The Series 3520 Trace Oxygen Analyzer is a light-weight, compact portable oxygen analyzer designed for industrial and commercial applications where accurate, spot oxygen measurements need to be made.
- Features and Benefits
- System Description
- Specifications
- Rear View Photo
- Download PDF Data Sheet
(Requires Adobe Acrobat Reader) - Contact Us
Features | Benefits |
State-of-the-Art Sensor Technology | High Precision Measurements |
Light Weight/Compact Design | Easy to Carry and Transport |
Rapid Speed of Respons | Senses Oxygen Changes in Seconds |
Built-in NICAD Batteries | Provides Hours of Continuous Operation |
Uses Standard NICAD’s | Replacement Batteries Found World-Wide |
Minimum Maintenance | Low Cost of Ownership |
System Description
The analyzer is powered from standard NICAD batteries that are mounted internally within the enclosure. Also included is an AC/DC adapter that when in use, allows the analyzer to be operated while the NICAD batteries are being recharged. Optional equipment includes a sample pump, pressure regulators, and sample filters. The Series 3520 is the product of choice with single measuring ranges from 0-50 parts per million to 0-10,000 parts per million.
The Series 3520 Portable Trace Oxygen Analyzer is a high precision instrument designed to provide accurate trace oxygen measurements in a variety of laboratory and process gases. The Series 3520 can be configured with one of several measuring ranges from 0-50 parts per million (ppm) to 0-10,000 ppm.
The Series 3520 is equipped with either a 3-1/2 or 4-1/2 digit liquid crystal display (depending on the range selected), built-in NICAD batteries, and an AC adapter that provides the ability to recharge the NICAD batteries even while powering the analyzer from the adapter. The 3520 features an advanced electrochemical oxygen sensor. The improved mechanical design of the sensor ensures longer life and virtually eliminates leakage of caustic electrolyte, a nagging problem associated with sensors that require periodic electrolyte maintenance. The output from the sensor is temperature compensated. In addition, the sensor is equipped with manual isolation valves so that during times of inactivity, the sensor can be kept inerted and ready for use.
Learn about about sample system handling for oxygen and carbon dioxide analyzers
A major advantage of the Series 3520 is that it does not require users to apply a correction factor to the readings when exposed to different gas compositions. With other analyzer types, if correction factors are not applied, readings can be off by a factor of three!
Back To Top
Specifications
Measurement Ranges: 0-50, 0-100, 0-500, 0-1,000, 0-5,000, and 0-10,000 PPM
Accuracy: ±1% of full scale
Linearity: ±1% of full scale.
Response Time: 90% of full scale in <20 seconds typical
Sensor Type: Electrochemical
Temperature Compensation: Standard
Operation Temperature Range: 40º to 100ºF (5º to 38º C)
Sample Gas Pressure Limits: 0.1 to 1.0 psig (1.04 kg/cm² to 1.10 kg/cm²)
Sample Flow Rate: 1.0 to 2.0 SCFH (0.5 to 1.0 liters/minute)
Power Source: Rechargeable NICAD batteries or 115 VAC/60 Hz using the AC adapter
Analog Output: Not available
Warranty: Two years electronics/1 year sensor
Enclosure: Polycarbonate-rated NEMA 1
Display: 3-1/2 or 4-1/2 digit liquid crystal display
Gas Connections: 1/4”compression fittings
Dimensions: D. 5.8” H x 8.8” W x 3.4” D
Weight: <4 pounds