>> CTC / LEAP PAL 氣相色譜進樣針
Hamilton offers a wide range of quality syringe options for the PAL GC and Combi PAL (Headspace) GC Autosamplers. 1. CTC / LEAP PAL 氣相色譜進樣針
S-Line syringes deliver exceptional performance for everyday use in GC autosampler injections at a great value. The C-Line syringe minimizes the potential for bent needles with a keyed flange design. The latest generation of Hamilton autosampler syringes is recommended by CTC for use in the popular GC PAL systems: · PAL GC-xt · PAL COMBI-xt · PAL COMBI-xt extended 1.1 S-Line 進樣針
S-Line syringes are the cost-effective choice for CTC PAL autosampler applications. S-Line syringes deliver great performance in everyday use for GC injections at an exceptional value. Fast injection speeds in GC analyses put considerable stress on syringe plungers and, as plungers wear the stresses increase, leading to broken syringes and unnecessary downtime and wasted money when samples cannot be analyzed. Hamilton syringes employ a fitting process that precisely fits each plunger to the matching barrel. This produces a plunger with minimal drag force and optimal wear characteristics that results in superior up time for the autosampler. 訂貨信息
1.2 C-Line 進樣針
C-Line syringes incorporate several unique design features that ensure superior performance. An improperly installed syringe can cause mis-injections or bent needles due to poor alignment. The unique flange alignment design aids in installation and results in fewer bent needles while the plunger button can be adjusted to prevent plunger tip damage. An innovative direct attachment design of the needle to the barrel minimizes sample carryover.
訂貨信息
2. CTC LEAP CombiPAL HD Headspace Syringes 頂空進樣針
Modern GC Headspace analysis requires injecting over large temperature ranges (e.g. ITEX analysis). Traditional headspace syringes come with a rubber O-ring sealed plunger which has a limited sealing performance at high temperatures. Hamilton's NEW headspace syringe with its unique, high-temperature plunger tip, is specifically designed for the CTC CombiPAL autosampler system. The High Dynamic (HD) plunger has been optimized for higher throughput in headspace techniques. The HD design by Hamilton sets a new standard for headspace syringe performance. Hamilton's solution: · New sealing system based on a novel metal spring allows working with enhanced tightness · Excellent performance over a large temperature range and temperature gradients · Increased life-time compared to traditional headspace syringes · Increased accuracy and reproducibility of headspace GC analysis
訂貨信息
3. CTC LEAP CombiPAL HDHT Headspace Syringes 頂空進樣針
Hamilton introduces a new headspace syringe featuring a unique needle attachment in combination with the High Dynamic (HD) plunger designed specifically for PAL COMBI–xt Headspace Autosamplers. Hamilton's solution: · Needle attachment is chemically inert, eliminating detached needles due to contact with organic, and chlorinated solvents · Temperature stability up to 200°C means a wider range of sample components can be analyzed · Spring-in-plunger design creates a dynamic seal between the plunger tip and the inside of the glass barrel for leak-free operation
訂貨信息
|
貨號 | 產(chǎn)品描述 |
67444-01 | 10 µL, Model 1701 N CTC SYR (6.6 mm), S-Line, Cemented Needle, 22s ga, point style 3 |
67446-01 | 25 µL, Model 1702 N CTC SYR (7.9 mm), S-Line, Cemented Needle, 22s ga, point style 3 |
67450-01 | 50 µL, Model 1705 N CTC SYR (6.6 mm), S-Line, Cemented Needle, 22 ga, point style 3 |
67452-01 | 100 µL, Model 1710 N CTC SYR (6.6 mm), S-Line, Cemented Needle, 22s ga, point style 3 |
67442-01 | 250 µL, Model 1725 N CTC SYR (7.9 mm), S-Line, Cemented Needle, 22 ga, point style 3 |
67448-01 | 500 µL, Model 1750 N CTC SYR (7.9 mm), S-Line, Cemented Needle, 22 ga, point style 3 |
1.2 C-Line 進樣針
C-Line syringes incorporate several unique design features that ensure superior performance. An improperly installed syringe can cause mis-injections or bent needles due to poor alignment. The unique flange alignment design aids in installation and results in fewer bent needles while the plunger button can be adjusted to prevent plunger tip damage. An innovative direct attachment design of the needle to the barrel minimizes sample carryover.
訂貨信息
貨號 | 產(chǎn)品描述 |
203194 | 10 µL, Model 1701 FN CTC SYR (6.6 mm), C-Line, Fixed NDL, 22s ga, point style 3 |
203073 | 10 µL, Model 701 FN CTC SYR (6.6 mm), C-Line, Cemented NDL, 22s ga, point style 3 |
203274 | 25 µL, Model 1702 FN CTC SYR (6.6 mm), C-Line, Cemented NDL, 22s ga, point style 3 |
203075 | 25 µL, Model 1702 FN CTC SYR (7.9 mm), C-Line, Fixed NDL, 22s ga, point style 3 |
203235 | 100 µL, Model 1710 FN CTC SYR (6.6 mm), C-Line, Cemented NDL, 22 ga, point style 3 |
203077 | 100 µL, Model 1710 FN CTC SYR (6.6 mm), C-Line, Fixed NDL, 22s ga, point style 3 |
202668 | 100 µL, Model 1710 RN CTC SYR, C-Line, NDL Sold Separately |
203079 | 250 µL, Model 1725 FN CTC SYR (7.9 mm), C-Line, Fixed NDL, 22 ga, point style 3 |
203349 | 500 µL, Model 1750 FN CTC SYR (7.9 mm), C-Line, Fixed NDL, 22 ga, point style 3 |
203081 | 1 mL, Model 1001 LTN CTC SYR (7.6 mm), C-Line, Fixed NDL, 22 ga, point style 3 |
203083 | 2.5 mL, Model 1002 LTN CTC SYR (9.65 mm), C-Line, Cemented NDL, 22 ga, point style 3 |
203085 | 5 mL, Model 1005 LTN CTC SYR (13.6 mm), C-Line, Cemented NDL, 22 ga, point style 3 |
2. X-Type 進樣針
X-Type syringes have a near zero carryover and a long-lasting plunger tip to meet the requirements of sensitive, high-throughput life science applications. The syringe glass barrel is polished and coated for chemical inertness and enhanced lifetime. The needle is deactivated and coated to reduce sample adsorption. Tests with critical samples like phospholipids, basic molecules and peptides have shown that carryover and absorption are reduced depending on the sample. The plunger’s life cycle is also improved.
訂貨信息
貨號 | 產(chǎn)品描述 |
204475 | 25 µL, X-Type Model 1702 FN CTC SYR (7.9 mm), Fixed NDL, 22s ga, point style 3 |
204379 | 50 µL, X-Type Model 1705 FN CTC SYR (7.9 mm), Fixed NDL, 22s ga, point style 3 |
204400 | 100 µL, X-Type Model 1710 FN CTC SYR (6.6 mm), Fixed NDL, 22 ga, point style 3 |
204452 | 100 µL, X-Type Model 1710 FN CTC SYR (6.6 mm), Fixed NDL, 22s ga, point style 3 |
3. CTC LEAP A200S Syringes
訂貨信息
貨號 | 產(chǎn)品描述 |
203560 | 10 µL, Model 1701 N CTC SYR (6.6 mm), Cemented NDL, 22s ga, 51 mm, point style 3 |
203566 | 100 µL, Model 1710 N CTC SYR (6.6 mm), Cemented NDL, 22s ga, 51 mm, point style 3 |