熙盛電氣數(shù)字電流表參數(shù)解析
熙盛電氣可編程數(shù)顯儀表適用于電力電網(wǎng)、自動(dòng)化系統(tǒng)中對(duì)電流、電壓、頻率、功率等電量參數(shù)進(jìn)行直接測(cè)量和顯示,具有精度高、穩(wěn)定性好、抗震動(dòng)等優(yōu)點(diǎn),帶有RS485數(shù)字通訊協(xié)議,傳輸距離達(dá)1.2公里??赏ㄟ^(guò)面板按鍵操作,隨時(shí)任意設(shè)置顯示倍率、通訊地址及波特率參數(shù),使用非常方便,數(shù)字教零、教調(diào)、精度高、性價(jià)比高,是CD194系列的生計(jì)產(chǎn)品,可替代原有的指針表。
ONE:FEATURES特點(diǎn)
◎Value measurement\ Four digits display
◎Three phase meter can display the three phase voltage or current of three LED rows A、B and C
at the same time.
◎Software calibration、No resistor inside ( high precision、good stability、long time working without calibration)
◎The programmable meter can arbitrary set the display value 1~9999 through the panel button.
◎Communication function、communication address and Baud rate can be choose.
◎Upper and lower limit Alarm function can be choose.
◎真有效值測(cè)量、整四位顯示
◎三排LED同時(shí)顯示A、B、C三相電壓或電流
◎軟件調(diào)校、內(nèi)部無(wú)電位器(精度高、穩(wěn)定性好、長(zhǎng)期工作免調(diào)校)
◎可編程通過(guò)面板按鍵任意調(diào)節(jié)顯示值1~9999
◎可選帶通訊功能、通訊地址、波特率
◎可選帶上下限報(bào)警控制功能
TWO:TECHNICAL SPECIFICATION技術(shù)指標(biāo)
Input | Input | voltage:500V(special can be made) |
current:、1A(special can be made) | ||
Overload | Last:1.2times | |
Instantaneous :voltage 2times /second、current 10times /second | ||
Extend | Match instrument transformer or electrical shunt to extend range. | |
Frequency | 50Hz ± 10% | |
Power | Voltage | AC 220V±10%(special can be made) |
Power consumption | < 2W | |
Display | LED | Four figures,display time of data update:1Second |
Display | 0~9999 | |
Precision | 0.5%~0.2% | |
Isolation Resist pressure | 2KV/50Hz/1min | |
Insulation resistance | ≥100MΩ | |
Average normal working time | ≥50000h | |
Working conditions | Environmental temperature:-25℃~55℃ | |
Relative humidity ≤93% non-corrosive gas sites. |
輸 入 | 輸入 | 電壓:500V(特殊可訂做) |
電流:、1A(特殊可訂做) | ||
過(guò)載 | 持續(xù)1.2倍 | |
瞬時(shí):電壓2倍/秒、電流10倍/秒 | ||
擴(kuò)展 | 配互感器或分流器擴(kuò)展量程 | |
頻率 | 50Hz ± 10% | |
電 源 | 電壓 | AC 220V±10%(特殊可訂做) |
功耗 | <2W | |
顯 示 | LED | 整四位,顯示數(shù)據(jù)更新時(shí)間:1S |
顯示 | 0~9999 | |
精度等級(jí) | 0.5%~0.2% | |
隔離耐壓 | 2KV/50Hz/1min | |
絕緣電阻 | ≥100MΩ | |
平均正常工作時(shí)間 | ≥50000h | |
工作條件 | 環(huán)境溫度:-25℃~55℃ | |
濕度≤93% 無(wú)腐蝕氣體場(chǎng)所 |
THREE: OUTLINE AND OPENING SIZE 外形和開(kāi)孔尺寸
外形代號(hào) (outline code) | 外形尺寸(outline size) | 開(kāi)孔尺寸(hole size) | |||
A(mm) | B(mm) | C(mm) | D(mm) | E(mm) | |
16槽形trough shape | 160 | 160 | 125 | 150 | 75 |
42方形squareness | 120 | 120 | 80 | 111 | 111 |
6方形squareness | 80 | 80 | 76 | 76 | 76 |
5槽形trough shape | 96 | 96 | 112 | 92 | 44 |
9方形squareness | 96 | 96 | 78 | 91 | 91 |
72方形squareness | 72 | 72 | 74 | 67 | 67 |
微方形tiny squareness | 48 | 48 | 112 | 45 | 45 |
FOUR : NOTE
1、The meter must be heated 15 minutes with the power on before use. (使用前,儀表需通電15分鐘)
2、Avoid vibrations or shock,excessive dust and noxious gas.(注意防止震動(dòng)和沖擊,不要在有超量灰塵和超量有害氣體的地方使用)
3、Input wire should not be too long,please use 2-core shielded cable if the measured signal input terminal is more long.(輸入導(dǎo)線不宜過(guò)長(zhǎng),如被測(cè)信號(hào)輸入端較長(zhǎng)時(shí)請(qǐng)使用雙絞屏蔽線)
4、If the input signal is super inposed with high-frequency noise, use a low-frequency filter. (若信號(hào)伴隨高頻干擾,應(yīng)在線里使用低頻過(guò)濾器)
5、If the meter won’t be used for a long time ,please connect power supply every three months, not less than 4 hours each time.(長(zhǎng)時(shí)間存放未使用時(shí),請(qǐng)每三個(gè)月通電一次不少于4小時(shí))
6、Long time for storing the meter should be in the shade ,with the environment temperature is -25℃~55℃,the relative humidity :≤93%,and non-corrosive gas sites.(長(zhǎng)期保存應(yīng)避開(kāi)直射光線,宜存放在環(huán)境溫度:-25℃~55℃,相對(duì)濕度≤93% 無(wú)腐蝕氣體場(chǎng)所)
7、If the meter no display that you should check –up the auxiliary power firstly , and the voltage should be fall within the prescribed limits.(如儀表無(wú)顯示,應(yīng)先檢查輔助電源,電壓是否在規(guī)定范圍內(nèi))
8、If display is abnormal state, please check-up if the input signal working correctly and the signal terminal tightened or not.(如顯示不正常,檢查輸入信號(hào)是否正常及信號(hào)接線端是否擰緊)
9、Except the PT has enough power , otherwise you can not use the PT signal as auxiliary power at the same time. Then can be ensure the meters working as normal.(除非PT有足夠功率,否則不能使用PT信號(hào)同時(shí)做為輔助電源,以保證儀表正常工作)
10、The screw of current terminal in the CT circuit must be tightened, ensure the in-wire and out wire be reliable , so as not to cause malfunction.(CT回路中的電流接線端子螺絲務(wù)必?cái)Q緊,保證進(jìn)/出線接觸可靠,以免產(chǎn)生故障)
相關(guān)產(chǎn)品