進(jìn)口高壓高溫不銹鋼電磁閥
德國(guó)雷普電磁閥總代理:深圳派克閥門(mén)有限公司
Germany LIP Solenoid Valve distributor: Shenzhen Parker Valve Co.
LIP中國(guó)總代理、產(chǎn)品選型、詳細(xì)產(chǎn)品參數(shù),感謝您選用德國(guó)雷普LIP品牌高壓電磁閥,我們將為您提供更節(jié)能、優(yōu)化的流體管道及設(shè)備的解決方案和產(chǎn)品服務(wù).
LIPDGARF進(jìn)進(jìn)口高壓高溫不銹鋼電磁閥作為自動(dòng)控制及遠(yuǎn)程控制的一個(gè)執(zhí)行器,它廣泛應(yīng)用在冶金、石化、輕紡、制藥、食品、煙草、國(guó)防、科研等各項(xiàng)領(lǐng)域,其流通的介質(zhì)分別為蒸汽、空氣、油、水、燃?xì)狻⒅评鋭┑取?br /> LIPDGARF pressure solenoid valve as an automatic control and a remote control actuator, it is widely used in the field of metallurgy, petrochemical, textile, pharmaceutical, food, tobacco, defense, scientific research, its circulation media are steam, air, oil, water, gas, refrigerants.
進(jìn)口高壓不銹鋼電磁閥工作原理working principle:
當(dāng)線圈通電,動(dòng)鐵芯吸合,先導(dǎo)閥口處于開(kāi)啟狀態(tài),使主閥塞上腔降壓,主閥塞因壓差開(kāi)啟,介質(zhì)流通。當(dāng)線圈斷電,動(dòng)鐵芯復(fù)位,先導(dǎo)閥口處于關(guān)閉狀態(tài),使主閥塞上腔升壓,將主閥塞壓下,電磁閥關(guān)閉.
When the coil is energized, the movable core pull, the pilot valve port is turned on, the main valve plug chamber pressure, because the pressure to open the main valve plug, medium flow. When the coil power, moving core reset, the pilot valve port is closed, the main valve plug chamber booster, the main valve plug depressed, the solenoid valve is closed.
技術(shù)參數(shù)Technical Parameters:
技術(shù)參數(shù):
產(chǎn)品規(guī)格: DN0.5~DN200
閥體材質(zhì): 不銹鋼
適用介質(zhì): 水、氣、油、蒸汽、燃?xì)?、腐蝕流體等
溫度范圍: -150~+550℃
介質(zhì)粘度: 小于50C St(大于時(shí)需定制)
防護(hù)性能: 防水、防爆(Exd IICT5)、防腐
接線方式: 接線座式;引線式;插頭式
控制方式: 常開(kāi)、常閉
電源電壓: DC12~127V; AC36~380V
連接方式: 內(nèi)螺紋、法蘭、外螺紋
泄 漏 量: 零
安裝維護(hù)Installation and maintenance:
1、現(xiàn)場(chǎng)安裝必須按照國(guó)家防爆危險(xiǎn)場(chǎng)所“電氣安全規(guī)程”中有關(guān)規(guī)定進(jìn)行。
2、電磁閥內(nèi)外接地,必須牢固可靠。
3、電磁閥引出電纜導(dǎo)線為三根,其中一根為接地線,另二根為工作導(dǎo)線。
4、電磁閥安裝前應(yīng)將管路內(nèi)部清洗干凈。
5、電磁閥有雜質(zhì)時(shí),進(jìn)口端前必須安裝密度0.5mm的過(guò)濾器。
6、安裝電磁閥時(shí)注意閥體上箭頭要求與介質(zhì)流向*。
7、電磁閥應(yīng)垂直安裝,線圈在上。
8、電磁閥維修時(shí)應(yīng)斷電后開(kāi)蓋,非電器人員不得拆卸電磁閥電氣部件。
1, on-site installation must be carried out in accordance with the national explosion-proof hazardous location "Electrical safety regulations" the relevant provisions.
2, the solenoid valve inside and outside the ground, must be solid and reliable.
3, the solenoid valve lead cable conductors for the three, which one is the ground wire, and the other two wires to work.
4, the solenoid valve is mounted inside the front line should be cleaned.
5, when the solenoid valve with impurities, must be installed before the inlet end of 0.5mm density filter.
6, pay attention to the arrow on the valve body in line with the medium flow requirements to install the solenoid valve.
7, the solenoid valve should be mounted vertically on the coil.
8, when the solenoid valve repair after opening the lid off, non-electrical personnel may not disassemble solenoid valve electrical components.