The PrimeTest 50 manual PAT testing machine is battery powered and handheld to allow for fast and efficient testing. A simple range of tests are selected at the push of a button - earthed appliance, double insulated appliance or mains cord test.
The LCD display shows a clear pass or fail result. The PrimeTest 50 is a great choice for those needing one of the most reliable and easy to use PAT testing machines available. Please Note: PrimeTest 50 does not have a backlight.
This PAT tester is ideal for all applications where in-house testing is being performed on a periodic basis by staff with limited experience.
The tester is capable of testing Class 1, Class 2, Cables and IT equipment, providing simple Pass/Fail results on a large clear display.
Earth Continuity
Test Current | +/- 200mA DC |
PASS/FAIL Threshold | 0.2ohms |
Insulation Resistance
Test Voltages | 500V DC |
PASS/FAIL Threshold | 2Mohms |
| |
IEC Lead Test
Tests Performed | Earth Continuity |
| Insulation Resistance |
| Live / Neutral Checks for o/c, s/c and crossed |
Circuit Tests
Power Socket Test
Input Voltage Range | 230V +10%, -15% AC |
Indicators | Phase to Earth Voltage |
| Phase to Neutral Voltage |
| Neutral to Earth |
Weight and Dimensions
Weight and Dimensions | 800g/11cm (w) x 5.5cm (d) 27cm (l) |
Power Source
Power Source | 6 x AA Type disposable cells |
Part number