MODEL | 8205 | 8210 |
INSULATION RESISTANCE |
| Range | Resolution | Accuracy |
Output Voltage, DCV | 30-1000 | 1 | ±(1% of setting+1V) |
Ouput Regulation DCV | ±(1% of output +1V) from no load to full load |
Output Ripple | <2% |
Discharge | Automatic Discharge of Device Under Test |
Indicator: Green<30V, Red>30V |
SETTINGS |
Low-Limit Resistance, MΩ | 0.1~999.9 | 0.1 | Same as Resistance Measurement |
1000~9999 | 1 |
10.0GΩ~50.0GΩ for Model 8205 10.0GΩ~200.0GΩ for Model 8210 | 0.1GΩ |
Delay Time, second | 1~999.9 | 0.1 | ±(0.1% of setting + 0.05sec) |
Dwell Time, second | 0, 0.1~999.0 (0=continuous) |
MEASUREMENT |
| Range | Resolution | Accuracy |
DC Voltage, V | 0.01~100.0 101-1000 | 0.1 1 | ±(1% of setting+1V) |
Resistance | 0.001MΩ~50.0GΩ for Model 8205 0.001MΩ~200.0GΩ for Model 8210 ,Auto Range | 0.001MΩ 0.01MΩ 0.1MΩ 1MΩ 0.01GΩ 0.1GΩ | 500–1000V 0.1MΩ - 1GΩ,± (2% of reading + 2 counts) 1GΩ - 20GΩ , ± (3% of reading + 2 counts) 20GΩ –50GΩ,±(10% of reading + 2 counts) 20GΩ–200GΩ,±(10% of reading + 2counts) 30–499V 0.1MΩ-1GΩ,± (3% of reading + 2 counts) 1GΩ - 20GΩ , ± (5% of reading + 2 counts) |
GENERAL |
Input Voltage AC | 115/230Vac±15%, 50/60Hz ± 5%, Fuse 1A/ Fast acting 250VAC |
PLC Remote Control | Inputs : Test , Reset, Interlock |
Outputs : Pass, Fail , Progressing |
Display | 4 Digits LED Display |
Terminations | High Voltage Output – Alden Socket |
Shielded Return – BNC Connector |
Safety | Built-in Smart GFI circuit,GFI trip current 450μA max, HV shut down speed: <1mS |
Calibration | Built-in software and external calibrated meters |
Environment | 0-40℃, 20-80%RH |
Dimension/Net Wight | 280mm(W)×89mm(H)×300mm(D)/ 4.5Kg |
STANDARD ACCESSORIES |
Power Cord(10A) | ×1 |
Fuses | ×2 (Including a spare contained in the fuse holder) |
Interlock Disable Key(1505) | ×1 |
Hipot Test Lead ,1.5m(1101) | ×1 |
BNC Connector Return Test Lead ,1.15m(1140) | ×1 |
*product specifications are subject to change without notice. |