- Compact design
- Customized V and C full scales* with no extracost
- Total protection against arcs, overloads and short circuits
- High reliability & efficiency
- Low stored Energy
- Air cooling
- Voltage and Current Outputs continuously adjustable from 0 to full scale
- High precision regulation
- V & C Setting and Monitoring from front panel or REMOTE
- Remote, Inhibit & Interlock functions
- Double Resonance Technology (ZVC)
- Automatic crossover
- Over Current Limitation and Protection functions
- Over Temperature Protection
- 3½ digit displays with polarity display
- Safety switch key
- Master-slaves architecture
* You can choose your own full scales (Vmax and Imax) even if these values are not available in standard. For example, you can get a 45 000 V generator based on 6 000 W model. In this case, you will get an Output Voltage adjustable from 0 to 45 000 V and an Output Current from 0 to 133.3 mA.
- Output Voltage and Output Current: Both Voltage Output and Current Output are continuously adjustable from 0 to 100 % (full scale).
- Voltage regulation Load Regulation: ±0.05 % of full voltage (for 0 - 100 % load change); ±0.01% available on request.
- Current regulation: Load Regulation: ± 0.05 % (for 0 - 100 % load change)
- Ripple + Noise: 0.1 % p-p
- Setting Time: < 100 ms typical,, 10 ms available on request
- Stability (after one hour warm-up): 0.01 % / hour, 0.03 % after / 8 hours of operating with constant load and ambiant temperature.
- Temperature Coefficient: 100 ppm/°C
- Operating Temperature: from 0 to 40°C
- Efficiency: > 90 % full load
- Recovery Time After Arc: < 1 mS
- Stored Energy: 1J / kW
- Air Cooling by air: Dust filter fans on front panel. Easily removable filters for cleaning.
- Main Voltage: 400 VAC ± 10 % 47 - 63 Hz 3 Phases + Earth
- Power factor: > 0.98
- Calibration: with probes periodically approved by Authorized Measurement Laboratories
- CE Marking
In local mode: by using 10 turns potentiometers resolution 0.05%
In remote mode: by an external 0 to 10 V Voltage
Line Regulation: ±0.05 % of full voltage ( for Main Voltage ±10 %); ±0.01% available on request.
Line Regulation ± 0.05 %: (for Main Voltage ± 10 %)
SR 5 kW Series SR 6 kW Series SR 8kW Series SR 10kW Series Voltage Current Model Current Model Current Model Current Model 300 V 16.67 A SR0,3-(X)*-5000 20.00 A SR0,3-(X)*-6000 26.67 A SR0,3-(X)*-8000 33.33 A SR0.3-(X)*-10000 700 V 7.14 A SR0,7-(X)*-5000 8,57 A SR0,7-(X)*-6000 11.43 A SR0.7-(X)*-8000 14.29 A SR0.7-(X)*-10000 1 KV 5.00 A SR1-(X)*-5000 6.00 A SR1-(X)*-6000 8.00 A SR1-(X)-8000 10.00 A SR1-(X)*-10000 2.5 KV 2.00 A SR2.5-(X)*-5000 2,40 A SR2.5-(X)*-6000 3.20 A SR2.5-(X)*-8000 4.00 A SR2.5-(X)*-10000 5 KV 1.00 A SR5-(X)*-5000 1.20 A SR5-(X)*-6000 1.60 A SR5-(X)*-8000 2.00 A SR5-(X)*-10000 10 KV 500 mA SR10-(X)*-5000 600 mA SR10-(X)*-6000 800 mA SR10-(X)*-8000 1.00 A SR10-(X)*-10000 15 KV 333 mA SR15-(X)*-5000 400 mA SR15-(X)*-6000 533 mA SR15-(X)*-8000 667 mA SR15-(X)*-10000 20 KV 250 mA SR20-(X)*-5000 300 mA SR20-(X)*-6000 400 mA SR20-(X)*-8000 500 mA SR20-(X)*-10000 30 KV 167 mA SR30-(X)*-5000 200 mA SR30-(X)*-6000 267 mA SR30-(X)*-8000 333 mA SR30-(X)*-10000 40 KV 125 mA SR40-(X)*-5000 150 mA SR40-(X)*-6000 200 mA SR40-(X)*-8000 250 mA SR40-(X)*-10000 50 KV 100 mA SR50-(X)*-5000 120 mA SR50-(X)*-6000 160 mA SR50-(X)*-8000 200 mA SR50-(X)*-10000 60 KV 83.3 mA SR60-(X)*-5000 100 mA SR60-(X)*-6000 133 mA SR60-(X)*-8000 167 mA SR60-(X)*-10000 80 KV 62.5 mA SR80-(X)*-5000 75 mA SR80-(X)*-6000 100 mA SR80-(X)*-8000 125 mA SR80-(X)*-10000 100 KV 50 mA SR100-(X)*-5000 60 mA SR100-(X)*-6000 80 mA SR100-(X)*-8000 100 mA SR100-(X)*-10000 120 KV 40 mA SR120-(X)*-5000 50 mA SR120-(X)*-6000 66.7 mA SR120-(X)*-8000 83.3 mA SR120-(X)*-10000 150 KV 33.3 mA SR150-(X)*-5000 40 mA SR150-(X)*-6000 53.3 mA SR150-(X)*-8000 66.7 mA SR150-(X)*-10000
*
P for Positive Polarity
N for Negative
R for Reversible option
F for Floating option.