FT-106A微粉堆積密度測定儀
FT-106AMicropowder bulk density tester
一. 參照標(biāo)準(zhǔn)standard:
ISO9136-2:1999(E)《磨料--堆積密度的測定--:微粉》
According to the international standard ISO9136-2:1999 (E), the technical requirements for” the measurement of the bulk density ofthe abrasive material,
工作原理:將待測的微粉裝入漏斗,微粉在自身的堆積作用下處于堆積狀態(tài)。當(dāng)電磁振蕩器啟動后,微粉在電磁振動的作用下,途徑流入測量桶中,將落入到測量筒中的微粉刮平,在天平上稱取刮平后測量筒中的微粉質(zhì)量,再除以測量筒的容積,就可以測出待測微粉的堆積密度
Working principle : Place the tested micropowderin the funnel, and the micropowder will be stable under its ownaccumulation.When start the electromagnetic oscillator, under the action ofelectromagnetic vibration, micro powder will follow into the measurement cylinder in particular ways andmethods, Scrape the micropowder which in measuring cylinder and make it leveling , weight the micropowder left in the measurementcylinder after leveling on the balance scale , then divided by the volume ofmeasuring cylinder, your can measure the bulk density of powder under test
二.參數(shù)資料Parameters:
漏斗材質(zhì):不銹鋼;Funnelmaterial: stainless steel;
漏斗尺寸:高度290mm;上口直徑190mm;出料口內(nèi)徑:28mm;出料口高度:38mm
Funnel size: height 290mm, upper diameter190mm, outlet inner diameter: 28mm, outlet height: 38mm
振動槽材質(zhì):不銹鋼Vibratingtrough material: stainless steel
振動槽尺寸:(210mm×40mm×30mm)±1mm
Vibrating trough dimensions: (210mm×40mm×30mm)±1mm
測量筒尺寸:內(nèi)徑64mm; 內(nèi)高度62.2mm
Measuring cylinder dimensions: innerdiameter 64mm, inner height 62.2mm.
測量筒容積: (200±0.5) cm3
Measuring cylinder volume: (200±0.5) cm3
測量誤差:≤±0.02g/cm3
Measurement error: ≤±0.02g/cm3
漏斗下口內(nèi)徑:28mm;量筒容積:200ml ; 漏斗出料口高度:38mm;被測微粉下落高度:140mm.
The inner diameter of funnel loweropening:28mm, cylinder volume: 200ml, funnel outlet height: 38mm, the droppingheight of the measured powder: 140mm.